1M60 Camera User’s Manual 25
DALSA C32-10010-01
Because this signal is internally OR’ed with the TRIGGER IN Sync input, care must
be taken to ensure the TRIGGER IN signal is equal to a logic 0 while in Serial
Trigger mode.
3.12
Controlling Frame Rate
The 1M60 allows you to control frame rate in three ways.
Free Running (Programmed Frame Rate): (default) The camera free runs
with the internally programmed frame rate time and integration time.
External Trigger/Internal Integration: The camera frame rate will be
controlled by the TTL pulse on the TRIGGER IN SMA connector. The camera
will integrate for the programmed integration time. (Reference section 3.10
Controlling Integration Mode)
External Integration: The camera frame rate will be controlled by the TTL
pulse on the TRIGGER IN SMA connector. The camera will integrate fas long
as the pulse is held high. In this mode, TRIGGER IN also controls integration.
(Reference section 3.10 Controlling Integration Mode)
Free Running (Programmed Fame Rate)
To specify programmed frame rate, you must set bit [7] of register 1 = 0 (Integrate
Mode = Internal), and bit [3] of register 1 = 0 (Trigger Mode = Internal). Next, write
the frame rate bit value to the Frame Rate register.
Example: Set the Frame Rate to 30 fps
1.0 Reference section 3.10 Triggering, Integration, and Frame Rate Overview to
ensure the desired frame rate can be supported for the selected binning and
integration modes.
2.0 Using the command 82h, set bit [7] of the data byte to 0 (Integration Mode =
Internal), bit [3] of the data byte to 0 (Trigger Mode = Internal), and bits [2:0]
of shutter control to 000.
NOTE: All bits within the register are written at one time. Ensure the correct
value for all bits are used when changing camera modes.
3.0 Use command 88h to set bits [6:4] of control register 3 to the integration time
value 001.
Value = 30 fps
Write Frame Rate LS Byte Write Frame Rate Center Byte
Command Value Command Value
Binary 1000 0010 0*** 0000 1000 1000 *001 ****
Hex 82h *0h 88h **h
External Trigger/SMA Connector
Refer to section 3.11 Controlling Integration Mode.
External Trigger/Serial Connector
Refer to section 3.11 Controlling Integration Mode.